9:10 am - 10:00 am CEST
45 minutes talk + 5 minutes Q&A
Artificial intelligence is increasingly transforming healthcare by extracting clinically relevant information from complex and multimodal data. Among these sources, the human face is a rich but sensitive channel: facial expressions may reveal emotional states, pain, discomfort, or changes associated with mental and neurological conditions. This keynote discusses facial emotion recognition as an emerging technology for healthcare, from methodological foundations to responsible clinical use. The talk will review computational approaches based on facial landmarks, Action Units, shallow machine learning, deep learning, and multimodal models combining facial appearance, motion, and voice. Particular attention will be given to dynamic analysis, micro-expressions, robustness in realistic conditions, and the trade-off between interpretability and performance. Healthcare applications include mental health monitoring, diagnosis and treatment support, pain detection, patient–clinician communication, clinical research, and empathetic artificial agents. The talk will finally address ethical, regulatory, and validation challenges, emphasizing that these systems should support, not replace, clinical judgement.
10:00 am - 10:30 am CEST
10:30 am - 11:00 am CEST
Oral presentations are assigned 15 minutes (12 minutes talk + 3 minutes Q&A)
Background: Suicidal risk after stroke is a serious clinical problem. Depression is a key predictor, but its effect may change when combined with anger expression and inflammation. It is also unclear whether the depression-related component of such a framework remains stable on external public data. Methods: We evaluated an explainable interaction-based framework on two datasets. The main analysis used a private cohort of 100 post-stroke patients, where suicidal risk was grouped into low, medium, and high levels using the Beck Hopelessness Scale. We modeled interactions between depression and anger-in, depression and anger-out, and depression and C-reactive protein (CRP) using regularized multinomial logistic regression. We also analyzed a public NHANES cohort of 5,390 adults, where suicidal ideation was defined using PHQ-9 item 9 and depressive symptoms were represented by PHQ items. Results: In the private cohort, both models showed good discrimination. The most stable finding was the interaction between depression and anger-out for the high-risk class (beta = 0.683, 95% CI [0.429, 0.940], sign consistency 100%), while depression and anger-in was weaker but still positive. The interaction between depression and CRP was suggestive but less robust. ALE stability further showed a highly consistent profile for outward anger (rho = 0.998), in contrast to inward anger (rho = 0.103). In NHANES, the depression-based model remained stable (AUC = 0.909 ± 0.019, AP = 0.306 ± 0.053), and the most stable predictors were DPQ060 and DPQ020, both with perfectly consistent ALE profiles (rho = 1.000). Conclusions: Post-stroke suicidal risk appears to be shaped by interacting pathways, with depression as the central component and outward anger as the most consistent psychological amplifier in the high-risk group. The NHANES analysis supports the external stability of the depression-related pathway, whereas the interaction findings remain more specific to the post-stroke setting.
Problem. Deep neural networks in clinical imaging fail silently under two key deployment threats: covariate shift from inter-site acquisition variability, and adversarial perturbations that cause confident misclassification. Gap. Existing methods address these failure modes in isolation and produce a single scalar uncertainty estimate that cannot explain why a prediction is unreliable. Method. We propose TSD-Net (Test-time Self-Diagnosing Network), which augments a standard classifier with a Self-Diagnosis Head (SDH) jointly learning three causally distinct diagnostic signals: domain shift score sd, adversarial likelihood sa, and confidence reliability sc. A tri-source training regime (clean, domain-shifted, adversarial) teaches the network failure semantics—enabling a multi-dimensional rejection gate that abstains with a structured clinical reason. Results. Across three random seeds on HAM10000 with cross-domain evaluation on ISIC 2019, TSD-Net achieves ECE = 0.043±0.002, domain-shift AUROC = 0.891±0.004, adversarial AUROC = 0.876±0.005, and 93.9% accuracy at 80% coverage consistently outperforming MC-Dropout, Deep Ensembles, Temperature Scaling, Energy Score, ODIN, and SelectiveNet. Impact. Unlike prior work estimating only uncertainty magnitude, TSD-Net disentangles multiple deployment risks within one unified test-time diagnostic framework, supporting differentiated clinical responses and improved workflow safety.
11:00 am - 12:30 pm CEST
Oral presentations are assigned 15 minutes (12 minutes talk + 3 minutes Q&A)
Brain connectivity studies increasingly use diffusion MRI tractography to build whole-brain structural networks as tractograms with millions of streamlines. But streamlines are variable-length polylines with irregular point spacing, which makes geometric processing and distance computation challenging, and complicates downstream tasks such as artifact detection, bundle identification, streamline manipulation, and tractogram comparison. To address this issue, common fixes either resample streamlines to a fixed length (distorting geometry) or learn distance-based embeddings (e.g., dissimilarity representations, autoencoders) that require aggressive resampling and often generalize poorly across subjects. Deep models also treat streamlines as unordered point clouds, discarding the edge relationships that define anatomical trajectories.
We present ECLIPSE (Edge-Convolution Latent Inference for Path/Stream Embedding), a geometry-aware framework that embeds streamlines by explicitly modeling point-to-point edges along the path. Using edge convolution to propagate information between neighboring vertices, ECLIPSE preserves sequential structure while capturing smoothness, curvature, and local anatomical context. Across datasets spanning different step sizes and tractography algorithms, ECLIPSE generalizes robustly to geometric and tractography variability, yielding more faithful embeddings for downstream tasks – including bundle identification and clustering – than existing streamline embedding methods.
Intracranial hemorrhage (ICH) analysis requires both accurate lesion localization and reliable subtype recognition.While deep learning has advanced ICH analysis, existing methods address segmentation and classification as independent tasks, overlooking the strong anatomical correlation between hemorrhage extent and subtype identity, and are further constrained by the scarcity of pixel-level annotations. We propose a two-phase framework for joint hemorrhage segmentation and multi-label subtype classification from 2D CT slices. In the supervised phase, a shared Wide-ResNet50-2 encoder is coupled with a UNet++ segmentation decoder and a lesion-guided classification head, where predicted hemorrhage masks serve as soft spatial priors for subtype recognition. In the semi-supervised phase, a warm-start Mean Teacher strategy leverages unlabeled CT slices through consistency regularization with confidence filtering applied only to the segmentation branch, while classification benefits indirectly through the shared encoder. Experiments on the Brain Hemorrhage Segmentation Dataset (BHSD) show that multi-task learning improves Dice by 11.48% absolute and macro-F1 by 5.45% absolute over single-task baselines. The semi-supervised stage further improves performance to 77.87% Dice and 65.50% macro-F1, demonstrating that segmentation-guided multi-task learning and unlabeled-data regularization are complementary for CT-based ICH analysis.
An accurate detection of Unruptured Intracranial Aneurysms
(UIAs) is crucial for evaluating the risk of rupture and, possibly, scheduling appropriate treatment strategies. Time-of-Flight Magnetic Resonance Angiography (TOF-MRA) is the preferred non-invasive imaging technique for visualizing cerebral vasculatures and aneurysms. However, traditional 2D image analysis methods often fail to capture the complex 3D
geometry of aneurysms. This work introduces an approach that transforms TOF-MRA images into 3D mesh representations which are subsequently analyzed via MeshCNN, a geometrical deep learning architecture designed for 3D mesh classification. To further enhance the architecture’s performances, we perform data augmentation; in this step, we introduce a synthetic bifurcation model capable of realistically mimicking the shapes of vessels and aneurysms. We evaluate the effectiveness of our approach
on a dataset comprising various aneurysm sizes and locations. The results demonstrated a significant improvement in detection accuracy and consistency.
Attention Deficit Hyperactivity Disorder (ADHD)
is a common neurodevelopmental disorder where early and
accurate diagnosis remains challenging. Resting-state functional
magnetic resonance imaging (rs-fMRI) and functional connec-
tivity networks (FCNs) have shown great potential for ADHD
identification, but existing deep learning methods are limited
by small sample sizes, inter-site variability, and poor preser-
vation of brain network topology during data augmentation.
To address these issues, we propose Symmetric Neurograph
Augmentation via Probabilistic diffusion Learning (SYNAPSE),
a novel diffusion-based framework for multi-site ADHD identi-
fication. The proposed method constructs multi-scale functional
neurographs from rs-fMRI data and introduces a symmetry-
constrained diffusion model to generate biologically meaningful
FCNs while preserving graph topology and network symmetry.
In addition, a spectral topology encoding module and cross-site
contrastive learning strategy are designed to improve structural
consistency and generalization across heterogeneous datasets.
Finally, an attention-guided graph transformer is employed for
ADHD classification and biomarker discovery. Experiments on
ADHD-200, Healthy Brain Network (HBN), and ABCD datasets
demonstrate that SYNAPSE outperforms existing methods interms of classification accuracy, robustness, and cross-site generalization while generating realistic functional brain networks with clinically meaningful biomarkers.
Current diagnostic methods for Attention Deficit Hyperactivity Disorder (ADHD) rely heavily on clinical evaluations and behavioral scales, characterizing largely subjective processes. Meanwhile, objective approaches such as EEG and fMRI are invasive, expensive, and not viable for routine use. In this context, computational methods based on computer vision and machine learning emerge as less invasive and potentially scalable alternatives, allowing for the automatic extraction of motor and behavioral patterns from videos. In this context, this work presents a literature review, conducted according to the PRISMA guidelines, on the use of artificial intelligence applied to the assisted screening of ADHD from 2018 to 2026. The results show that approaches based on body movement, eye movement, virtual reality, and multimodal fusion achieve high predictive performance, with a notable emphasis on multimodal models. However, many studies still use small sample sizes and internal validation, limiting clinical generalization and characterizing research gaps for future investigation.
Early detection of dementia, especially its most common form, Alzheimer’s disease (AD), remains a critical challenge, particularly in low-resource communities where access to specialist assessment and neuroimaging is limited. The objective of this study is to develop a scalable, non-invasive, and cost-effective speech-based method for early detection of AD. The approach is evaluated on speech samples from 237 participants performing the Cookie Theft picture description task. Acoustic patterns are captured using Symbolic Aggregate Approximation (SAX), while linguistic information is represented through embeddings from a pre-trained language model. These multimodal features are integrated using a Gated Recurrent Unit (GRU) network with ensemble learning. The main results demonstrate an accuracy of 97.08\%, outperforming existing state-of-the-art speech-based AD detection methods. The significance of this work lies in its proposed high-performing model, accessibility and scalability, offering a practical screening solution that can facilitate earlier intervention, reduce healthcare disparities, and support wider deployment of AD assessment in low-resource settings.
12:30 pm - 1:30 pm CEST
1:30 pm - 3:00 pm CEST
Oral presentations are assigned 15 minutes (12 minutes talk + 3 minutes Q&A)
Classification of electrocardiogram (ECG) signals presents significant challenges due to their complexity and high dimensionality, requiring advanced machine learning techniques for accurate multi-class and multi-label classification. In this work, we propose ECG-KanFormer, a novel architecture that combines Kolmogorov-Arnold Networks (KANs) and Transformers, representing the first integration of these two technologies for ECG signal analysis. KANs, based on the Kolmogorov-Arnold representation theorem, are well suited for approximating complex continuous functions and effectively modeling the non-linear characteristics of ECG data. In the proposed architecture, KAN modules replace the standard linear layers within the Transformer, enhancing its capability to capture intricate non-linear dependencies in ECG signals. Extensive experiments demonstrate that ECG-KanFormer achieves state-of-the-art performance across multiple evaluation metrics for multi-class and multi-label ECG classification. These results highlight the effectiveness of the proposed end-to-end framework and demonstrate the promising potential of KAN-enhanced Transformer architectures for medical signal analysis and computer-aided diagnosis.
Learning semantically organized representations from electroencephalography (EEG) is a fundamental requirement for non-invasive brain-computer interfaces and other healthcare-oriented neural signal applications. However, visual decoding from EEG remains challenging due to the noisy, high-dimensional, and data-limited nature of scalp recordings. In this work, we propose a Dual-Stage Self-Attention framework for contrastive EEG-image alignment, in which channel-wise self-attention first captures inter-electrode dependencies while preserving temporal resolution, followed by temporal self-attention that aggregates information over time through a learnable
[CLS] token to generate a compact EEG representation. The resulting EEG embedding is aligned with a frozen pretrained SigLIP image embedding space using a label-aware contrastive learning objective that considers samples from the same class as positive pairs. Extensive experiments on the EEGCVPR40 benchmark demonstrate that the proposed approach outperforms CNN- and Transformer-based baselines with comparable model complexity. Ablation studies further show that delaying channel aggregation is a key design choice, highlighting the effectiveness of the proposed architecture for EEG representation learning and cross-modal alignment.
Training reliable arrhythmia detection systems requires large and diverse electrocardiogram (ECG) datasets; however, clinical ECG collections are often scarce, class-imbalanced, and subject to strict privacy regulations. In this work, we present a physiologically validated synthetic ECG generation pipeline in which a large language model (LLM) serves exclusively as a clinical knowledge encoder, generating JSON-based physiological constraint envelopes that are verified against established cardiology guidelines. These constraints regulate rejection sampling across three complementary generative models: interpolation, MLP WGAN-GP, and 1D-CNN-GAN. Experimental evaluation under an inter-patient protocol on the MIT-BIH Arrhythmia dataset demonstrates that unconstrained generators frequently produce physiologically implausible signals, while the proposed constraint-based framework substantially improves the clinical validity of the synthesized ECG beats. Statistical equivalence testing confirms strong morphological agreement between real and synthetic signals, and constrained data augmentation preserves or improves arrhythmia detection performance, particularly for supraventricular beat classification. These results highlight the importance of physiological constraint enforcement as a fundamental requirement for synthetic ECG generation and motivate the integration of additional local morphological validation criteria to achieve clinically reliable synthetic data for healthcare applications.
Parkinson’s disease (PD) is characterized by motor impairments that significantly affect gait, making gait analysis a valuable approach for non-invasive and objective disease detection. In this work, we propose a deep learning framework for PD detection from RGB-D skeletal gait sequences acquired from a dataset of 117 participants, including healthy controls and patients across Hoehn and Yahr severity stages 1 to 4. Individual gait cycles are represented as multidimensional time series of 3D joint coordinates and analyzed using a hybrid architecture that combines one-dimensional convolutional neural networks for local feature extraction with a Temporal Convolutional Network (TCN) for long-range temporal modeling. To enhance both classification performance and interpretability, the proposed model replaces the conventional softmax classifier with a proxy-based deep metric learning layer, where learnable class-specific proxies serve as reference points in the latent embedding space. Experimental results demonstrate that the proposed architecture achieves an accuracy of 95.45% and an F1-score of 89.41%, while maintaining robust performance across different stages of disease severity. These findings highlight the effectiveness of combining CNNs, TCNs, and proxy-based metric learning for accurate and interpretable Parkinson’s disease detection from gait analysis.
Motor impairments, including tremor, bradykinesia, gait abnormalities, and postural instability, are common manifestations of neurological and movement-related disorders, motivating the development of objective and continuous assessment methods. In this work, we introduce EgoInertia-MI, a multimodal benchmark dataset that combines synchronized egocentric video and wearable inertial measurement unit (IMU) signals for motor impairment analysis. The dataset comprises 19 upper- and lower-body activities performed by healthy participants simulating three levels of motor impairment severity: no impairment, mild impairment, and severe impairment. We establish two benchmark tasks—action recognition and motor impairment severity estimation—and evaluate a range of unimodal and multimodal baseline approaches. Experimental results demonstrate that egocentric vision provides rich information for motor impairment assessment, while multimodal fusion of visual and inertial data achieves the best performance, reaching a Macro-F1 score of 0.78 for severity estimation and 0.93 for action recognition. These findings highlight the potential of integrating egocentric vision with wearable sensing to enable privacy-aware, ecologically valid, and robust motor assessment systems.
Automated seizure detection from scalp electroencephalography (EEG) remains a challenging problem due to substantial inter-patient variability, which limits the generalization capability of population-trained models to unseen individuals. In this work, we propose a patient-adaptive seizure detection framework based on cluster-aware modeling and lightweight Temporal Convolutional Networks (TCNs) for pediatric EEG analysis. Patients are grouped according to their ictal spectral characteristics, and dedicated LightweightTCN models are trained for each cluster under a strict leave-one-patient-out evaluation protocol. The proposed framework supports both zero-shot inference and patient-specific adaptation through fine-tuning with a limited number of labeled EEG windows. The LightweightTCN architecture integrates trainable per-channel softmax gating for interpretable spatial attention and squeeze-and-excitation modules for feature recalibration. Experiments on all 24 patients of the CHB-MIT Scalp EEG Database demonstrate that the proposed approach achieves a mean F1-score of 0.711 and an AUPRC of 0.869 in zero-shot settings, while patient-specific fine-tuning significantly improves performance, reaching an F1-score of 0.822 and an AUPRC of 0.905. Additional improvements are observed in MCC and Cohen’s Kappa, together with a substantial reduction in clinical false alarms after applying persistence filtering. These results demonstrate the effectiveness of cluster-based personalization and lightweight adaptation strategies for robust, leakage-free, and patient-aware seizure detection in pediatric EEG monitoring.
3:00 pm - 3:30 pm CEST
3:30 pm - 5:00 pm CEST
Oral presentations are assigned 7 minutes (6 minutes talk + 1 minute Q&A)
The increasing prevalence of retinal diseases, including Diabetic Retinopathy, Glaucoma, and Cataracts, highlights the need for efficient and scalable diagnostic solutions. Traditional manual screening methods require expert intervention and are often time-consuming, limiting their applicability for large-scale deployment. In this work, we introduce Eye Intel, an AI-driven multi-disease retinal analysis system based on deep learning models for real-time diagnosis and clinical decision support. The proposed framework integrates a complete diagnostic workflow including image preprocessing, feature extraction, multi-model inference, risk assessment, and automated report generation. The system is implemented using a FastAPI backend with a React-based frontend, incorporating role-based access control and dedicated interfaces for technicians and patients. To improve transparency and trust, Grad-CAM-based explainable artificial intelligence techniques are employed to highlight image regions contributing to model predictions. Experimental results demonstrate competitive performance, achieving accuracy values from 86.29% for multi-class Diabetic Retinopathy classification to above 93% for binary classification tasks such as Glaucoma and Cataract detection. The proposed system also provides efficient response times and robust diagnostic capabilities, demonstrating its potential as an assistive platform for large-scale retinal screening and healthcare applications.
Pathologic complete response (pCR) represents an important surrogate marker of long-term survival in non-small-cell lung cancer (NSCLC), motivating the investigation of clinical factors associated with treatment outcomes. In this retrospective study, we analyze structured Electronic Health Record (EHR) data to identify relevant predictors of pCR, assess the stability of these associations across different machine learning models, and explore potential patient subgroups. A cohort of 101 NSCLC patients is evaluated using Logistic Regression, Random Forest, and XGBoost within a stratified group cross-validation framework based on patient identifiers. The best-performing models are further investigated through a comprehensive interpretability pipeline combining correlation analysis, mutual information, univariate statistical tests, permutation importance, SHAP analysis, Recursive Feature Elimination, k-Means clustering, and feature interaction analysis. Logistic Regression achieves the highest test performance with a Matthews Correlation Coefficient (MCC) of 0.372. The consensus analysis reveals consistent associations between pCR and clinical variables related to lymph-node clearance, post-surgical staging, treatment regimen, and histological characteristics across different modeling approaches. Subgroup analysis further identifies patient clusters associated with reduced pCR probability, particularly linked to incomplete molecular profiling. These findings demonstrate the potential of interpretable machine learning applied to structured EHR data for uncovering robust clinical associations and supporting personalized treatment analysis in lung cancer.
Early detection of Alzheimer’s Disease (AD) through handwriting and drawing analysis represents a promising approach for improving accessibility to diagnostic tools, particularly in resource-limited communities. In this work, we investigate the role of demographic fairness in artificial intelligence models for AD detection based on handwriting and drawing data acquired through low-cost smart pens and tablets. While recent AI approaches have demonstrated promising diagnostic performance, potential disparities across demographic groups remain an important concern. This study analyzes handwriting and drawing patterns within Normal Control (NC) and AD populations across different demographic subgroups to assess whether such variations may introduce unfair model behavior. The findings reveal that demographic groups exhibit differences in handwriting and drawing characteristics; however, these variations do not necessarily translate into biased AI predictions. Nevertheless, the integration of multiple sensitive attributes can increase performance disparities and potentially affect model fairness. These results highlight the importance of incorporating fairness-aware analyses into AI-based AD detection systems to ensure reliable, equitable, and clinically applicable decision-making.
Vision-Language Models (VLMs) have shown promising capabilities for medical image interpretation; however, their reliability and safety in clinical environments remain uncertain. In this work, we present a comprehensive evaluation of five state-of-the-art VLMs for fetal ultrasound analysis across eight structured clinical questions. Using expert sonographer annotations as ground truth, we assess model performance through macro-averaged F1-score for multi-label tasks, exact-match accuracy for categorical predictions, and mean absolute error (MAE) for gestational age estimation. Furthermore, we introduce a four-level hallucination severity taxonomy and analyze clinical safety through false-alarm and over-escalation rates. Experimental results reveal significant limitations in current VLMs, with low anatomical structure recognition performance, high false-alarm rates in normality assessment, frequent over-escalation in clinical recommendations, and substantial errors in gestational age estimation. The findings demonstrate that existing VLMs are not yet suitable for autonomous clinical deployment and emphasize the need for robust human oversight, improved medical reasoning capabilities, and dedicated safety validation protocols before integration into healthcare workflows.
Markerless gait analysis enables non-invasive assessment of Parkinson’s Disease (PD) through video-based motion analysis, avoiding the need for physical markers or wearable sensors. However, joint-angle trajectories are directional measurements defined on a circular manifold, and conventional statistical descriptors designed for linear data may not accurately capture their underlying distributions. In this work, we investigate the effectiveness of circular statistical descriptors for representing angular gait signals in supervised PD classification. Using a public vision-based gait dataset and ViTPose for pose estimation, joint-angle trajectories are characterized through two matched feature families: a standard linear-statistics representation and a circular-statistics representation. Both approaches are evaluated under the same supervised learning framework, combining feature selection, recursive feature elimination, and multiple classifiers across repeated subject-level train–test splits. The objective is to assess whether circular descriptors provide comparable or improved discriminative information rather than maximizing classification performance. Experimental results show that circular statistics achieve performance comparable to conventional descriptors and, in some scenarios, provide improvements, particularly in more challenging classification settings and PD subject identification. Moreover, robust circular descriptors demonstrate increased resilience when angular distributions are affected by pose estimation inaccuracies. These findings highlight circular statistics as a valuable geometry-aware representation for markerless gait analysis and AI-based Parkinson’s disease assessment.
Radiomics analysis relies on texture descriptors to characterize medical images, but traditional gray-level co-occurrence matrix (GLCM) approaches are highly sensitive to image rotation due to their dependence on discrete directional offsets. In this work, we extend the Differentiable-GLCM framework, previously introduced as a continuous-space formulation based on radius-weighted neighborhoods, by incorporating directional aggregation to achieve rotation-invariant texture representation. Three aggregation strategies are investigated: discrete directional averaging, continuous angular integration for an isotropic formulation, and an efficient spatial weighting approach that approximates the integrated solution. Experiments conducted on rotated 2D planar and 3D volumetric medical images demonstrate improved rotational consistency and feature stability compared with conventional GLCM methods and the original direction-dependent Differentiable-GLCM formulation. The proposed approaches are evaluated through Frobenius norm analysis, showing particularly strong improvements for higher-order texture descriptors. The resulting directionally aggregated Differentiable-GLCM provides a compact, rotation-robust, and differentiable texture representation suitable for radiomics applications, variational segmentation methods, and integration into modern neural network pipelines.
Automated analysis of medical images plays a key role in computer-aided diagnosis by enabling efficient and accurate detection of multiple pathologies in large-scale clinical scenarios. In this work, we propose MV-CT-Net, a multi-view deep learning architecture designed for multi-label thoracic pathology detection from 3D chest CT scans. The proposed framework jointly exploits axial, coronal, and sagittal views to integrate complementary anatomical information and improve contextual understanding of volumetric data. To address the severe class imbalance between frequent and rare diseases, we introduce a class-specific threshold optimization strategy aimed at improving sensitivity and overall classification performance. Experiments conducted on the CT-RATE benchmark demonstrate that MV-CT-Net achieves competitive results compared with existing state-of-the-art approaches across multiple evaluation metrics, while enabling the detection of a broader range of thoracic abnormalities. These findings highlight the effectiveness of multi-view context fusion for enhancing deep learning-based chest CT analysis and supporting automated clinical decision systems.
Flow Matching (FM) models provide a powerful generative framework by learning ordinary differential equations (ODEs) that transport Gaussian noise toward complex data distributions. Since these ODEs can also be integrated in the reverse direction, conditional FM models naturally define an inverse mapping from images to label-conditioned latent representations. In this work, we investigate inverse flow dynamics as an interpretable mechanism for medical image classification. We demonstrate that when an image is inverted using its correct class condition, the resulting latent representation exhibits stronger Gaussian-like characteristics, whereas incorrect class conditions preserve structured image information. To quantify these differences, we introduce spectral descriptors, including spectral flatness, low-frequency energy, anisotropy, and radial spectral slope, together with cosine similarity measures between input images and inverse outputs. Experiments on MNIST validate the effectiveness of the proposed inverse-flow features, achieving 95.19% classification accuracy using only cosine similarity and spectral slope. Furthermore, evaluation on the CAMUS echocardiography dataset for cardiac view classification shows that inverse-flow features achieve 92.50% test accuracy and an average precision of 0.884 for distinguishing correct and incorrect label inversions. These findings highlight inverse-flow analysis as a compact and interpretable approach that connects conditional generative modeling with medical image classification.
Understanding how human behavior reflects both transient emotional states and stable individual differences in social cognition is a key challenge in affective computing. In this work, we investigate emotion-related behavioral patterns during an affect-labeling task by integrating Hand Tracking (HT) and Eye Tracking (ET) signals. Participants observed emotionally evocative images and expressed perceived emotions through handwriting-based responses, while gaze behavior was recorded using Tobii Pro Glasses 3 and graphomotor activity was captured through a Wacom One tablet. Demographic information and Theory of Mind (ToM) measures were also incorporated to analyze individual differences in social cognition. Multiple classification models, optimized through evolutionary algorithms, were trained for emotion recognition, while SHAP-based explainability techniques were employed to identify the contribution of behavioral features. Experimental results show that handwriting-related features provide the strongest contribution to emotion classification, capturing embodied affective responses through motor behavior. Conversely, eye-tracking features, collected before motor execution, emerge as relevant predictors of ToM-related traits, revealing stable physiological markers of mental-state attribution. These findings demonstrate that multimodal behavioral signals encode complementary aspects of affective processing and highlight the importance of separating perceptual mechanisms from motor responses for a deeper understanding of embodied emotional behavior.
Deploying deep learning models for medical image analysis in resource-constrained environments requires adaptation strategies that achieve high performance while maintaining low training costs and compact model storage. In this work, we investigate the integration of convolutional inductive biases into a frozen, Low-Rank Adaptation (LoRA)-adapted MedMAE Vision Transformer (ViT) for both classification and segmentation tasks. Through a controlled experimental analysis, we reveal a task-dependent behavior when replacing the original linear patch embedding with a trainable Convolutional Neural Network (CNN) stem. While the CNN-based tokenization improves classification performance on chest X-ray benchmarks, it consistently reduces segmentation accuracy on a skin lesion dataset. Ablation studies examining different CNN-stem configurations show that alignment, distribution-matching, and bypass strategies are unable to recover the original no-stem performance, suggesting a potential mismatch between CNN-generated token distributions and the pretrained ViT representation. Additional experiments comparing plain ViT + LoRA, multi-scale ViT feature extraction, and dual-encoder architectures indicate similar segmentation performance across alternatives, suggesting a task- and dataset-dependent performance plateau. Based on these findings, we provide practical recommendations for parameter-efficient medical vision adaptation: convolutional tokenization can benefit classification tasks, while segmentation is better addressed through standard or multi-scale ViT + LoRA approaches using a shared frozen backbone.
Breast cancer is one of the most frequently diagnosed cancers worldwide, and early detection through mammographic screening plays a crucial role in improving patient outcomes. However, manual interpretation of mammograms remains a challenging and time-consuming process, motivating the development of reliable computer-aided diagnosis systems. In this work, we present a comparative evaluation of deep learning architectures for breast lesion segmentation and detection in multi-source mammography datasets. We introduce DSU-Net (Dense Spatial U-Net), a novel U-Net-based architecture that combines dense connectivity patterns and spatial attention mechanisms to improve lesion representation and localization. The proposed model is compared with a VGG16-U-Net transfer learning approach and a Faster R-CNN detection framework using multiple mammographic datasets, including INbreast, MIAS, and DMID. DSU-Net integrates dense feature reuse, spatial attention-based lesion highlighting, and a hybrid Dice, Focal, and Binary Cross-Entropy loss function. Experimental results demonstrate strong segmentation performance under consistent annotation settings; however, cross-dataset variability caused by differences in acquisition protocols and annotation strategies remains a significant challenge. Transfer learning with a pretrained VGG16 backbone shows improved robustness in heterogeneous scenarios, while Faster R-CNN provides complementary detection capabilities. These findings highlight the importance of annotation consistency and dataset harmonization, in addition to architectural improvements, for effective multi-source medical image analysis.
Extreme annotation scarcity poses significant challenges for anatomical landmark detection, shifting the focus from fully supervised learning toward template-based landmark transfer methods. In such scenarios, average localization accuracy alone is insufficient, as a small number of severe landmark misplacements can substantially compromise downstream clinical measurements. In this work, we investigate one-shot hand X-ray landmark detection from a reliability-oriented perspective under a strict evaluation protocol that employs a single labeled template and no unlabeled target images. Rather than introducing a new detector, we propose Topology-Aware Foundation-Model Matching (TAFM), an inference-time enhancement that augments template-based matching with image-specific anatomical priors estimated from coarse correspondences. The inferred priors are used to constrain candidate landmark selection and guide local refinement through a prior-gated matching strategy. To better characterize model robustness, we introduce complementary reliability metrics, including landmark-level severe failure counts, image-level severe-case rates, maximum per-image localization error, and review-trigger statistics, alongside the conventional mean radial error (MRE). Experimental results on the 300-image Hand X-ray benchmark demonstrate that TAFM achieves state-of-the-art one-shot landmark detection performance, reducing the mean radial error from 1.655 mm to 1.340 mm and substantially decreasing severe localization failures. These findings highlight the value of reliability-aware evaluation and topology-guided refinement for anatomical landmark detection under extreme annotation constraints.
Automated yoga pose assessment has emerged as a promising solution for AI-assisted rehabilitation, remote physiotherapy, and privacy-preserving wellness monitoring. However, accurately distinguishing subtle pose variations while maintaining robustness to viewpoint changes remains a significant challenge. In this work, we propose SkeleGraphAttNODE (SGAN), a skeleton-based deep learning framework that combines graph neural networks, multi-view Transformers, and Neural Ordinary Differential Equations (Neural ODEs) for efficient and privacy-aware yoga pose assessment. The proposed architecture integrates three key components: a graph-based kinematic encoder that models anatomical joint relationships using Graph Convolutional Networks (GCNs) and a parallel global MLP branch, synthetic multi-view augmentation generated through 360-degree rotations of skeletal representations, and a Transformer encoder with cross-view self-attention followed by Neural ODE-based continuous-time latent evolution. Operating exclusively on anonymous skeletal joint coordinates, the framework preserves user privacy while effectively modeling spatial and temporal dependencies across multiple viewpoints. Experimental evaluation on the Yoga-82 skeleton benchmark demonstrates that SGAN achieves a top-1 classification accuracy of 88.41% using only 76,306 trainable parameters, outperforming existing skeleton-based methods and several image-based approaches while maintaining a compact architecture suitable for deployment on wearable devices and telehealth edge platforms.
5:00 pm - 5:15 pm CEST